Shandong ZHISO Environmental Tech Co., Ltd. is a joint company specialized in design & develop & selling of the instrument of environmental protection. ZHISO company is a professional R & D and sales company, mainly engaged in the UV detection method of ozone gas concentration principle and development of UV & infrared light absorption detection. We have our own manufacturer : Zibo Zhiprer Automation Technology Co., Ltd that mainly engaged in the production of UV ozone detector/ ozone gas analyzer.ZHISO company has it's own brand " ZHISO" and the main products are about:Ozone analyzer / Water quality / Toxic and harmful gas detector / Ozone generator. ZHISO company rely on the advantages & experience of high-level technical talents, to focuse on new products development. We are willing to cooperate with high-tech companies to work .
2.Product Introduction  Â
UV-200AT desktop ozone analyzer
The principle:UV dual light absorption method, used to detect the outlet concentration of ozone generator in real time.
The characteristic:desktop ozone analyzer,continuous running & automatic zeroing,to guarantee the stability.
The brand:
 Â
The patent NO.:ZL 2017 2 0109915.5
A.General description
The UV-200AT analyzer is mainly used for ozone concentration measurement in the pipeline of ozone generator, which can continuously detect ozone concentration in the outlet generator.
Based on the Lambert Law of Bill, by measuring the change of the intensity of the light signal before and after the UV absorption of the ozone to calculate the current ozone concentration. The equipment uses the advanced dual light UV light source system with the intelligent management system of the lamp tube, which can make the UV lamp tube reach the measuring state quickly after the machine is opened.Â
The device purge automatically at a certain time to ensure the stability of the zero point and prevent the zero drift from affecting the detection accuracy. The gas flow, pressure and flow rate remain unchanged at the time of zeroing, so as to prevent the impact of air flow on the zeroing and ensure the equipment can run continuously for 24 hours a day.
Â
Display resolution:0.01 g/m3;
Gas flow:0.8L±0.2L/min;
Input pressure:<0.1MPa;
Zero drifting:<±0.3%.FS(MAX:±0.6g/m3);
Sampling Caliber:Φ6(6mm*4mm);
Error rate:±0.5%;
Communication mode:RS-485;
Output mode:4-20mA,line;
Power Supply:AC 110-220V;
Dimensions: 260mm(length)×120mm(width)×230mm(depth);
Free warranty:12months(main engine);
Remark:1mg/L=1g/m3=467PPM;
Standard configuration: ozone destruct
Â
Detection method:UV absorption method with high accuracy;
Light source system:Imported long life UV lamp (wavelength 253.7nm);
Using method:Outdoor installation, waterproof, dustproof instrument, 24 hours continuous operation, configuration of waterproof power and signal connector
Cuvette system:Foreign separation cuvette technology, no leakage, anti high pressure, anti gas impact of high flow sampling
Intelligent compensation:Built-in light source , automatic compensation function;
Automatic zeroing:Autozero at a certain interval, manual mode or automatic mode can be selected to ensure the detection accuracy.
Data display:High clear digital backlight display, data clear;
Output function:4-20mA current signal and RS485 communication;
D.Product structure
Front panel:display window  Indicator light  zeroing button
Back panel:inlet / outlet signal output manual/auto zeroing switch
(Remark:If there is a difference between the instructions and the instrument signs, the instructions shall be taken as the standard)
1.RS485+:digital signal output RS485+Â Â Â Â Â Â Â Â Â Â 2.RS485-:digital signal output RS485-
3.4-20mA:Â Current output 4-20mA+Â Â Â Â Â Â Â Â Â Â Â Â Â 4. 4-20mA: Current output 4-20mA- G
E. Connection diagram Â
3. Issues of concern
A. Payment Terms:
1.T/T , PAYPAL, WU, 100% prepaid.
2. lead time 3-5days after payment
B. Our Service:
1. All products and accessories have been 100% tested before shipping.
2. We provide 12 months waranty on the host for non-deliberate damage
C. F&Q:
Q1. Can i have a sample oeder
A1: The sample oeder to test are welcomed at the first time.
Q2:How about your production capacity and quality control?
A2: We have written instructions for incoming & inline & final inspection and testing        All the qualified products must be pass the 100% audit by QE staff. And the failed products will be clearly marked and seperated to repair and re-inspect.
Q3: How can i get a good price?
A3: We are 100% sure that we can provide you the most competitive price with high values.Pls trus t us and attache your detail request, oeder quantity, delivery mode, payment terms.Â
Â
Shandong ZHISO Environmental Tech Co., Ltd. is a joint company specialized in design & develop & selling of the instrument of environmental protection. ZHISO company is a professional R & D and sales company, mainly engaged in the UV detection method of ozone gas concentration principle and development of UV & infrared light absorption detection. We have our own manufacturer : Zibo Zhiprer Automation Technology Co., Ltd that mainly engaged in the production of UV ozone detector/ ozone gas analyzer.ZHISO company has it's own brand " ZHISO" and the main products are about:Ozone analyzer / Water quality / Toxic and harmful gas detector / Ozone generator. ZHISO company rely on the advantages & experience of high-level technical talents, to focuse on new products development. We are willing to cooperate with high-tech companies to work .
2.Product Introduction  Â
UV-200AT desktop ozone analyzer
The principle:UV dual light absorption method, used to detect the outlet concentration of ozone generator in real time.
The characteristic:desktop ozone analyzer,continuous running & automatic zeroing,to guarantee the stability.
The brand:
 Â
The patent NO.:ZL 2017 2 0109915.5
A.General description
The UV-200AT analyzer is mainly used for ozone concentration measurement in the pipeline of ozone generator, which can continuously detect ozone concentration in the outlet generator.
Based on the Lambert Law of Bill, by measuring the change of the intensity of the light signal before and after the UV absorption of the ozone to calculate the current ozone concentration. The equipment uses the advanced dual light UV light source system with the intelligent management system of the lamp tube, which can make the UV lamp tube reach the measuring state quickly after the machine is opened.Â
The device purge automatically at a certain time to ensure the stability of the zero point and prevent the zero drift from affecting the detection accuracy. The gas flow, pressure and flow rate remain unchanged at the time of zeroing, so as to prevent the impact of air flow on the zeroing and ensure the equipment can run continuously for 24 hours a day.
Â
Display resolution:0.01 g/m3;
Gas flow:0.8L±0.2L/min;
Input pressure:<0.1MPa;
Zero drifting:<±0.3%.FS(MAX:±0.6g/m3);
Sampling Caliber:Φ6(6mm*4mm);
Error rate:±0.5%;
Communication mode:RS-485;
Output mode:4-20mA,line;
Power Supply:AC 110-220V;
Dimensions: 260mm(length)×120mm(width)×230mm(depth);
Free warranty:12months(main engine);
Remark:1mg/L=1g/m3=467PPM;
Standard configuration: ozone destruct
Â
Detection method:UV absorption method with high accuracy;
Light source system:Imported long life UV lamp (wavelength 253.7nm);
Using method:Outdoor installation, waterproof, dustproof instrument, 24 hours continuous operation, configuration of waterproof power and signal connector
Cuvette system:Foreign separation cuvette technology, no leakage, anti high pressure, anti gas impact of high flow sampling
Intelligent compensation:Built-in light source , automatic compensation function;
Automatic zeroing:Autozero at a certain interval, manual mode or automatic mode can be selected to ensure the detection accuracy.
Data display:High clear digital backlight display, data clear;
Output function:4-20mA current signal and RS485 communication;
D.Product structure
Front panel:display window  Indicator light  zeroing button
Back panel:inlet / outlet signal output manual/auto zeroing switch
(Remark:If there is a difference between the instructions and the instrument signs, the instructions shall be taken as the standard)
1.RS485+:digital signal output RS485+Â Â Â Â Â Â Â Â Â Â 2.RS485-:digital signal output RS485-
3.4-20mA:Â Current output 4-20mA+Â Â Â Â Â Â Â Â Â Â Â Â Â 4. 4-20mA: Current output 4-20mA- G
E. Connection diagram Â
3. Issues of concern
A. Payment Terms:
1.T/T , PAYPAL, WU, 100% prepaid.
2. lead time 3-5days after payment
B. Our Service:
1. All products and accessories have been 100% tested before shipping.
2. We provide 12 months waranty on the host for non-deliberate damage
C. F&Q:
Q1. Can i have a sample oeder
A1: The sample oeder to test are welcomed at the first time.
Q2:How about your production capacity and quality control?
A2: We have written instructions for incoming & inline & final inspection and testing        All the qualified products must be pass the 100% audit by QE staff. And the failed products will be clearly marked and seperated to repair and re-inspect.
Q3: How can i get a good price?
A3: We are 100% sure that we can provide you the most competitive price with high values.Pls trus t us and attache your detail request, oeder quantity, delivery mode, payment terms.Â
Â
UV Ozone Detector Dual Light Absorption Method to Test Ozone Concentration
Model NO.: UV-200AT
Trademark: ZHISO
Transport Package: Box
Specification: 260mm*120mm*230mm
Origin: China
HS Code: 9027100010
Model NO.: UV-200AT
Trademark: ZHISO
Transport Package: Box
Specification: 260mm*120mm*230mm
Origin: China
HS Code: 9027100010
1.Company Introduction
B. Technical parameters
Range:0-200g/m3NTP(Optional range:0-100g/m3,0-200g/m3,0-250g/m3);C.Product features
Principle:based on Longbow Bill's law, accurately measured by the principle of photometric absorption.
1.Company Introduction
B. Technical parameters
Range:0-200g/m3NTP(Optional range:0-100g/m3,0-200g/m3,0-250g/m3);C.Product features
Principle:based on Longbow Bill's law, accurately measured by the principle of photometric absorption.