Analytical pump and conveyor type: Tandem double-piston reciprocating pump, microprocessor controlled stroke, variable speed construction: chemically inert, non-metallic PEEK pump head and flow path PH: 0-14 aqueous solution and reversed solvent compatible control mode : Through the front panel or through chameleon software full control; TTL or relay switch selectable maximum operating pressure: 35Mpa (5000psi)
Pressure fluctuation: <1.0%
Flow rate range: 0.05-5.0 mL/min in increments of 0.01;
Flow accuracy: <0.1%
Flow accuracy: ±0.1%,
Piston seal cleaning: Double pump head, continuous cleaning pressure alarm limit when connecting washing liquid: upper limit 0-35Mpa or 0-5000psi in one unit increment (MPa or psi); lower limit can be set one unit lower than the upper limit.
Vacuum Degassing (Optional): Automatic Column Heating Operating Temperature Range: Environment +5°C to 60°C
Temperature stability: ±1°C
Temperature accuracy: ±2°C (at 40°C)
Eluent automatic generator concentration range: 0.1-100 mM
Flow rate range: 0.1-3.0mL/min
Maximum operating pressure: 21Mpa (3000psi)
Maximum solvent concentration: Anion: 25%Mathanol; Cation: Solvent-free conductivity detection circuit and flow cell type: Microprocessor - Digital signal processor Linearity: 1% at 1mS Resolution: 0.00238nS
Detection range: digital mode 0-15000μS;
Filter: start time from 0 to 10 seconds, user selectable temperature compensation: fixed at 1.7% for 1°C
Conductivity cell temperature control temperature range: environment +7°C to 55°C
Temperature stability: ≤0.01°C
Conductivity Cell Electrode: Passivated 316 Stainless Steel Conductive Cell Body Material: Chemically Inert Polymeric Material Conductance Cell Volume: <1 μL
Chi-plus heat exchanger: low differential maximum pool operating pressure: 10MPa
Suppressor control power supply:
AESR, 0-150mA, 1mA increments;
SRS, 0-500mA, 1mA Incremental Physical Specifications Power Supply: 100-240V AC, 50/60Hz (Automatic sensing and regulation)
Voltage range: 90-265V AC, 47-63Hz
Instrument operating temperature: 4-40°C (40-104°F)
Operating Humidity Range: 5-95% Relative Humidity, Non-condensing Control Mode: Controlled by chameleon software, TTL or delay switch can be selected. Two delayed outputs, two TTL outputs, four programmable input USB communication ports: One input, two fixed USB input ports Leak detection: built-in, optical sensor size (h × w × d) 22.1in × 8.8in × 21in; 56.1cm x 22.4cm x 53.3cm
Weight: 54 lbs, 24.5 kg AS40 Autosampler Specifications Vial Size and Texture: 0.5mL or 5mL Vial, Polyvial
Sample capacity: 11 trays 6x5mL or 8x0.5mL
Minimum liquid supply: 0.5mL bottle: 0.17mL/time 5mL bottle: 1.7mL/time per bottle Injection time: 1, 2 or 3
Injection method: Loop: Rapid injection (about 4 mL/min)
Concentration: 0.4mL/min (0.5mL bottle) under 690kPa (100psi) back pressure
Or 0.1mL/min (5mL bottle)
Voltage: 90-165Vac, 47-63Hz
Volume: 28.7X36.3X44.5cm (11.3X14.3X17.5in.)
Weight: <8.9kg (<195 lb)
Zhengzhou Zhongpai Launches New Ion Chromatograph
ICS-2000 is a new-generation ion chromatography system introduced by the United States Dai'an Company, which brings ion chromatography technology to a new level. ICS-2000 is the world's first chemical reagent-free ion chromatography (RFIC) equipped with a fully automatic eluent generator, including a high-precision double-plunger pump, an eluent generator, and a conductivity detector. With a temperature-controlled conductivity cell and a heated oven where columns and suppressors can be placed, the ICS2000 ion chromatograph can be compatible with any type of suppressor technology and analytical column from Diane.