Material Selection:
1. Frame: 2MM thicknesses cold-roll Stainless steel.
2. Motor: Germany SEW brake motor (outer), power 0.75KW, power supply 220V.
3. Control system: Imported Japan Mitsubishi converter and PLC to control of electric box (150%1HZ)
4. Opening & closing speed: 0.6-1.5m/s (adjustable).
5. Safety Device: Korea Photocell Sensor, emergency stopping reaction when sensing obstacles.
6. Curtain: France high-density polyester fiber and the surface coating processing, thickness 0.8MM, variety colors can be chose: Red, yellow, blue, green, orange, gray, white, transparent, etc. Tensile strength: 4000/3500N/5cm, tear strength 600/600N. Fire-proofing level: German standard DIN75200 Usage temperature: -30 ° C +70 ° C.
7. Wind resistant: The Aluminium alloy Reinforce Girder to increase wind resistant effect.
8. Curtain replacement function: Aluminium alloy Reinforce Girder is loaded between 2 pieces Curtain, can be replaced easily if any curtain broken, save your cost.
9. Transparent window: 1.2MM thickness transparent PVC window, size and location is up to your request, more safer.
10. Seal: Seal brush are Installed inside the guides, and the special bottom design, to fit any uneven ground.
11. Cotrolling way: Push button + radar sensor, very convenient.
12. Limiting Switch: Mechanical limiting switch, easily and exactly.
13. Emergency STOP: With emergency stop button on control panel, can stop easily by
Hand once disconnect or accident
14 Fault recovery function: All Hongfa's production is with fault recovery function, system will self-recovery after power cut off.
15. Delivery time: About 7 business days with contract and deposit confirmed.
16. Pyament item: 50% before production, and the other 50% before shipment.
17. Warranty Details: We provide 12 months warranty for all doors and accessories (except man-made disasters, Irresistible natural disasters, ect^).
We have many professional engineers with rich experience, qualified products, perfect service system, and good cooperation relationship with many famous companies.
High Speed Stacking Door, High Speed Stack Door, PVC high speed stacking door, Rapid stacking door, Fast stacking door SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfahsrs.com
Solenoid valve selection common sense
I. Security: do not pay attention to safety that will produce a disaster! 1. Corrosive media: the choice of plastic valve solenoid valve and stainless steel; for the strong corrosion of the media must use isolation diaphragm. Example CD-F. Z3CF. Neutral medium, copper alloy should also be used as the valve material of the solenoid valve, otherwise, the valve shell often rust off, especially when the action is not frequent. Ammonia valves can not use copper. 2. Explosive environment: you must choose the appropriate level of explosion-proof products, open-air installation or dust should be more occasions use waterproof, dustproof varieties. 3. Solenoid valve nominal pressure should exceed the maximum working pressure tube. Applicability: Does not apply to spend money to buy things, but also add trouble! 1. Dielectric Characteristics 1.1 Solenoid valves of different types are selected for gas, liquid or mixed state. For example, ZQDF is used for air, ZQDF-Y is used for liquid and ZQDF-2 (or -3) is used for steam. Otherwise, it may cause malfunction . ZDF series of multi-function solenoid valve is available in the gas. Liquid. The best time to state the media state, the installation users do not have to adjust. 1.2 different medium temperature product specifications, or the coil will burn, seal aging, seriously affect the life of life. 1.3 Medium viscosity, usually below 50cSt. If more than this value, diameter greater than 15mm with ZDF series of multi-function solenoid valve for special order. Path less than 15mm set high viscosity solenoid valve. 1.4 Media cleanliness should be equipped with a recoil filter valve in front of the solenoid valve, the pressure is low fashion can choose direct acting diaphragm solenoid valve for example CD-P. 1.5 If the medium is directional and does not allow backflow ZDF-N and ZQDF-N need to be used in both directions, please make a special request. 1.6 medium temperature should be selected within the allowable range of the solenoid valve. 2.Pipeline parameters 2.1 According to the media flow requirements and pipe connections choose the valve port and model. For example, the small diameter selection CA5 and Z3F for one pipe to two pipes, ZDF-Z1 / 2 for medium or large diameters. Another example is the control of the convergence of two pipelines, please choose ZDF-Z2 / 1. 2.2 According to the flow and the valve Kv value selected nominal diameter, but also optional with the pipe diameter. Please note that some manufacturers are not marked with Kv value, often the size of the valve hole is smaller than the interface diameter, must not be greedy price low and misleading. 2.3 working pressure minimum working pressure differential above 0.04Mpa is optional indirect pilot; minimum working pressure close to or less than zero must be used direct or step-by-step direct type. 3. Environmental conditions 3.1 The maximum and minimum temperature of the environment should be selected within the allowable range, if there is any need for special order made over. 3.2 Ambient high relative humidity and rain drops and other occasions, the election should be waterproof solenoid valve 3.3 frequent vibrations in the environment, bumps and shocks and other occasions should choose a special breed, such as marine electromagnetic valve. 3.4 In a corrosive or explosive environment should give priority to the use of corrosion resistance according to safety requirements 3.5 Environmental space is limited, please use multi-function solenoid valve, because it eliminates the need for bypass and three manual valves and easy online maintenance . 4. Power Condition 4. 1 According to the type of power supply, were selected AC and DC solenoid valve. In general AC power access convenience. 4.2 voltage specifications exhausted preferred AC220V.DC24V. 4.3 Power supply voltage fluctuations are usually used in the exchange of +% 10% .- 15%, DC allows ±% 10 or so, if ultra poor, to take measures to stabilize the voltage or make special order requirements. 4.4 should be selected according to the power capacity of the rated current and power consumption. Should pay attention to AC starting VA value is higher, in the lack of capacity should be preferred indirect induction solenoid valve. 5. Control accuracy 5.1 Ordinary solenoid valve only open and close two positions, high precision control parameters and parameters require stable multi-position solenoid valve; Z3CF three normally open solenoid valve, with micro-Kai, fully open and closed three Kinds of flow; ZDF-Z1 / 1 combination of multi-function solenoid valve with full open, big open, small open, full open four flow. 5.2 Operating time: refers to the electrical signal is turned on or off to the completion of the main valve action time, only the company's patented multi-function solenoid valve can be opened and closed separately adjusted, not only to meet the control accuracy requirements, but also to prevent water hammer damage. 5.3 Leakage The sample given on the value of leakage for the commonly used economic level, if too high, please make a special order. Third, the reliability: unreliable will damage the entire system! 1, working life, this is not included in the factory test project, a type test project. In order to ensure the quality of regular manufacturers should be selected brand-name products. 2, work standard: long-term work system, repeated short-term work system and short-term work system three. The Company's conventional products are long-term working system, that is, the coil allows long-term power work. · China Building Materials Network - building materials for a long time to open the valve only a short time off, it should be used normally open solenoid valve. Used in short-time working system and the volume is very large, special orders can be made to reduce power consumption. 3, the working frequency: high frequency of operation, the structure should be preferred direct-acting solenoid valve, the power to listen to the preferred exchange. 4, the reliability of the motion Strictly speaking, this test has not yet officially included in the professional standards of our solenoid valve, to ensure that the quality should be selected regular manufacturers brand-name products. In some occasions, the number of actions is not much, but the reliability requirements are very high, such as fire protection, emergency protection, must not be taken lightly. Particularly important, you should also take two double insurance. Economies: Ineconomy is one of the criteria used to waste capital, energy and even life, but it must be based on a safe, applicable and reliable economy. Economy is not only the selling price of the product, but also the priority given to its function and quality as well as the cost of installing maintenance and other accessories. More importantly, the cost of a solenoid valve in the entire automatic control system in the entire automatic control system and the production line is minimal, if you seek a cheap and missed the early damage caused by the group is huge. In short, economy refers not only to the product price, but to the product's cost performance to price ratio. Solenoid valve selection should follow the safety, suitability, reliability, economic four principles in turn