The application case of intelligent equipment for ammonia alarm in sludge treatment plant brought by non-eye-sight technology is a case of general direction, rather than the case of installing an ammonia gas alarm device in a specific sludge treatment plant. How to use online ammonia alarm equipment in sludge treatment plant? Floor Standing Type Air Conditioner The floor standing type a/cs series include all types of floor standing type a/cs which suitable for different markets, include floor standing type a/cs with R410A and R22 gas, power supply of 220~240v/50Hz/1ph, 230v/60Hz/1ph, 380~415v/50Hz/3ph and 380~415v/60Hz/3ph. Standing Air Conditioning,Floor Standing Air Conditioner,High Efficency Floor Standing Ac,Floor Standing Type Air Conditioner Foshan Dinghan Electrical Technology Co., Ltd , https://www.fsdinghanelectrical.com
Sludge treatment plants have a lot of ammonia in the production process. Because ammonia gas is a colorless gas and has a strong odor-stimulating gas, it burns the mucous membranes of the skin, eyes, and respiratory organs. Excessive inhalation can cause lung swelling. Even death. Therefore, protection against ammonia gas in sludge treatment plants is very necessary and must be well prevented. No eye-sight science and technology joined hands with sludge treatment plant ammonia gas alarm intelligent equipment application case, to create a safe production of sludge treatment plant.
Many people do not understand the role of the sludge treatment plant and the operating principles, but also do not know that the sludge treatment plant will produce a large amount of ammonia in the process of sludge treatment. Therefore, no eye-sight technology has brought sludge, such as concentration, conditioning, dehydration, stabilization, drying, or incineration, to sludge reduction, stabilization, and harmless processing. What should be done to produce ammonia gas in the process of harmless treatment of this sludge treatment plant?
In order to solve the problem that the sludge treatment plant may produce ammonia during the sludge treatment process, common measures, such as wearing gas masks and anti-corrosion wearable equipment, are no longer able to do a good job of safety prevention. Eyeless technology aims at solving this problem by developing and designing an ammonia gas leak detection device that is specially used for ammonia treatment in sludge treatment plants. It can quickly, accurately, and stably detect ammonia concentration and take intelligent protection measures. The hazards are completely annihilated at the bud stage.
It is usually necessary to judge the quantity and installation position of the ammonia gas detector used in the sludge treatment plant, followed by the fixed installation, then the commissioning test, and finally the normal maintenance operation.
1. The number of ammonia alarm detectors used in the sludge treatment plant Since the individual probes of the ammonia alarm detector can detect the orientation of 20-30 square meters, it is a good judgment for ammonia in relatively closed environments such as workshops and other places. If the number of gas alarm detectors is used, only the square volume of the detection environment needs to be divided by 20-30 square meters.
For open-air environments such as outdoor use, the number of ammonia gas detectors used in a sludge treatment plant needs to be considered from a safety point of view. At this time, the point where the ammonia gas leaks (pipeline interface, etc.) and safety detection are specified. It is necessary to install the ammonia gas leakage alarm device. In this case, it is necessary to customize the number of ammonia gas alarm probes for the specific environment.
2. Sludge treatment plant ammonia alarm installation location Online ammonia alarm device is divided into two parts: the probe and the alarm controller host. The probe is installed in the operation site, and the gas alarm control host is installed in the monitoring room. Easy to monitor environment. Here, the installation position of the ammonia gas alarm device in the sludge treatment plant is mainly introduced for the installation position of the ammonia gas alarm probe. Select the location where ammonia gas can easily leak to install the ammonia gas alarm equipment, and install the ammonia gas alarm probe at the location where the operator's work environment does not affect the normal operation.
3, sludge treatment plant ammonia gas alarm debugging, testing sludge treatment plant installed ammonia gas alarm equipment, you need to test and commission the equipment operation, in order to ensure that the supporting equipment can efficiently detect safety leakage, and Timely measures are taken to achieve ammonia protection of the sludge treatment plant in a true sense. Debugging the ammonia alarm device is very simple, just plug in the power cable and see if each probe and host display is normal. It is also very easy to test the ammonia alarm device. Take a certain amount of ammonia gas and place it in the probe part of the ammonia gas alarm. When the ammonia gas concentration appears and reaches the lower explosion limit, an alarm warning will be issued and the equipment will be installed. Start linkage settings such as solenoid valves and exhaust fans.
Sludge treatment plant ammonia alarm device application case According to the manufacturer's layout there is a certain difference in the difference, for this reason, no eye-sight science and technology brings sludge treatment plant ammonia gas alarm device application case is a general case, and It is not a specific sludge treatment plant ammonia gas alarm equipment installation case. If you need to know in detail the application case of an ammonia gas alarm device in a sludge treatment plant or a sludge treatment plant, please pay attention to the technology without eyesight or consult us.