Safety equipment cabinet specifications do you correct?

Electrical safety equipment cabinets Before the use of safety power equipment cabinets , it is necessary to check and confirm that there are no cracks in the insulation parts, no aging, no insulation layer shedding, no serious injuries, etc., and no looseness, no rust, no breakage, etc. in the fixed connection parts. The question of the appearance of the insulating part should be used after passing the insulation test. Did you do it right?

I. Safekeeping of Safe Electrical Appliances and Cabinets

The safety equipment cabinet should be stored in a dry and ventilated safety equipment room at -15 to 35 degrees Celsius and 80% relative humidity.

Safe cabinets should be equipped with suitable cabinets, shelves, and storage of unqualified safety tools and other items.

The portable grounding cable should be stored on a special rack. The number on the rack should be consistent with the number of the grounding cable.

Insulating baffles and insulating covers shall be stored in racks that are dry indoors, above 200 mm above the ground, or in dedicated cabinets. Wipe dust before use. If the surface is lightly scratched, it should be treated with insulating paint.

Second, the use and inspection of safety power tool equipment safety equipment

Before the use of safety equipment cabinets should be visual inspection;

Insulating operating rods, electroscopes and measuring rods: The allowable operating voltage should correspond to the equipment's voltage rating;

Before using the short-circuit grounding cable, check whether it is in good condition. If loose strands, broken strands, severely damaged jackets, loose jigs, etc. are found, use of them is prohibited.

Insulating baffles can only be used at voltage levels below 35kV

Before using the helmet, check it is in good condition

Belts and belts and ropes should have sufficient mechanical strength.

Buckle and climbing board: Metal parts deformation and rope (band) damage prohibited. Special anti-skid measures should be taken for the use of foot clasps and climbing boards in special weather conditions.

Third, safety equipment cabinet test.

All types of safety tools and apparatus shall undergo type tests, factory tests, and periodic tests in use prescribed by the State, and shall be well documented.

Newly purchased safety tools can be put into storage after passing the test.

"Electrical safety tools" refers to various special tools and devices that protect the personal safety of workers against accidents such as electric shock, burn, fall, and fall. After the safety tools have passed the test, they shall be affixed with the certificate at a place that does not obstruct the insulation performance.

The electrical and mechanical tests of the safety equipment cabinet may be carried out by each unit in accordance with the test standard and cycle, and may also be commissioned by a qualified experimental research institution.

All kinds of insulation safety tools test items, cycles and requirements should be in accordance with the relevant provisions