1. INTRODUCTION: 2. APPLICATIONS: 3. STANDARDS:
Our products are rigorous in manufacturing,
high quality and reliable in operation. Our products are exported to many
countries and are well received by users. We off OEM services to global
customers and we can manufacture slurry pumps or spare parts according to the construction drawings
and samples. The parts can be made of nonmetallic materials, include:
1.rubber materials
The rubber materials are suitable for conveying abrasive
slurry or corrosive slurry without sharp particles (such as river sand) or fine
particles (d<0.5mm).
2.Polyurethane elastomeric materials
The polyurethane elastomer materials have physical
dynamic properties similar to rubber, but have better wear resistance than
rubber, especially in working conditions of wet media such as water and oil,
and their wear resistance is usually several times better than ordinary rubber
materials.
Nonmetallic Material Spare Parts Nonmetallic Material Spare Parts,Nonmetallic Fabricated Materials,CNC Nonmetallic Material Spare Parts,Quality Nonmetallic Material Spare Parts,Rubber liner part,Nonmetallic Material Parts Shijiazhuang Soarho Machinary Co.,Ltd , https://www.xhslurrypump.com
This is High quality brightness Tester PN-48B .
The brightness meter is mainly used to test the whiteness of diversified objects such as paper and board,pulps and chemical fiber, textile, plastic, ceramic, enamel, fecula, salt, white cerement, porcelain clay and French chalk, etc. It can also be used to test the optical performance of sheet materials, for example, opacity test.
Paper, Board, Pulps, Chemical fiber, Textile, Plastic, Ceramic, Enamel, Fecula, Salt, White cerement, Porcelain clay and French chalk etc.
ISO 2469, ISO 2470, ISO 2471, GB/T 7933, GB/T 7974, GB/T 8940.2, GB/T 1840, GB/T 2913, GB/T 13025.2, GB/T, 1543, ISO 2471, GB/T 10339, GB/T 5950 Etc.
4. FEATURES:
1). Measure the Blue Reflectance Factor (R457) of samples. Blue Reflectance Factor is so called "Blue Whiteness" or "ISO Brightness".
2). Analyze the sample to find out whether it contains any fluorescent brightener. If so, measure the fluorescent whiteness further, namely whitening rate.
3). Measure the opacity, transparency, light scattering coefficient and light absorbing coefficient.
NO.
ITEM
SPECIFICATION
1
This instrument complies with GB3978-83; Standard illuminator and illuminating--viewing conditions.
2
Simulate D65 illuminator to illuminate. Adopt d/o illuminating--viewing geometrical coanditions. Diameter of the diffusion sphere is 150mm and diameter of the testing hole is 25mm.
3
Light absorber is provided to eliminate the effect of specular reflection. Peak wavelength of spectral power distribution of R457 whiteness optical system is 457nm and its half-width is 44nm.
4
Measure and display the whiteness, Fluorescent whiteness (whitening rate) and opacity (%) etc. digitally.
5
Indication error:
0.50%
6
Sample size:
Test plate diameter should not be less than 30mm while sample thickness should not exceed 40mm.
7
Power supply:
160V-260V, 50Hz, 0.3A
8
Measure time:
3s
9
Working condition:
Temp.0-40oC, relative humidity<85%.
10
Size and weight:
L×W×H=365×260×425mm, 11kg
Â