DV-8200 / Du-8200 UV/Vis Spectrophotometer

Model NO.: DV-8200/DU-8200
Dispersive Element: Grating Spectrometer
Light Number: Monochromator
Certification: RoHS, ISO9001
Customized: Non-Customized
Wavelength Range: 190-1100nm
Spectral Bandwidth: 2.0/4.0nm
Wavelength Setting: Manual, Resolution 0.1nm
Stability: <0.002A/H (500nm,0A)
Power Requirements: AC 22090-250V;50/60Hz
Net Weight / Gross Weight: 8.2kgs / 13kgs
Trademark: Drawell
Transport Package: Box
Specification: 431x318x195mm
Origin: Shanghai
HS Code: 9027300000
Model NO.: DV-8200/DU-8200
Dispersive Element: Grating Spectrometer
Light Number: Monochromator
Certification: RoHS, ISO9001
Customized: Non-Customized
Wavelength Range: 190-1100nm
Spectral Bandwidth: 2.0/4.0nm
Wavelength Setting: Manual, Resolution 0.1nm
Stability: <0.002A/H (500nm,0A)
Power Requirements: AC 22090-250V;50/60Hz
Net Weight / Gross Weight: 8.2kgs / 13kgs
Trademark: Drawell
Transport Package: Box
Specification: 431x318x195mm
Origin: Shanghai
HS Code: 9027300000
 

 
DV-8200 / DU-8200
UV/VIS Spectrophotometer

8200 series spectrophotometer is the ideal instrument for education and QC laboratories. They are simple to fit a curve by using your standard. They are widely used in colleges and quantitative analysis lab.

Features
Small fine design, space saving
The excellent optical and electric system
Low noise and Low stray light
Large LCD display (128*64 Dots), can display curve
High quality grating, detector and lamps
Data and Curve can be stored in real-time
Auto setting WL, auto Blank
Easy to change Pri-aligned lamps
Reinforced baseboard and bracket assures durability
Function:
Photometric: T%, Abs
Quantitative: Standard Curve
System Utility
* WL Scan (Spectrum Scan) (PC)
* Time Scan (Kinetics) (PC)
* DNA/Protein Test (PC)
* Multi-WL Test (PC)
 
 Specifications:
Model DV-8200 DU-8200
Wavelength Range 320-1100nm 190-1100nm
Spectral Bandwidth 2.0nm or 4.0nm optional
Optical System Single Beam, Blazed Holographic Grating (1200 lines/mm)
Wavelength Accuracy ±0.8nm
Wavelength Repeatability ≤0.2nm
Wavelength Setting Auto, Resolution 0.1nm
Photometric Range 0~200%T, -0.3­~3A, 0~9999C
Photometric Accuracy ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T)
Photometric Repeatability ≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.2%T (0~100%T)
Stray Light ≤0.1%T(220/360nm)
Scan Speed High, Medium, Low.  Max.1000nm/minute
Baseline Flatness ±0.003A
Stability ±0.002A/h (500nm,0A)
Noise ≤0.2%T/3min (250/500nm,0%T); ≤0.5%T/3min (250/500nm,100%T)
Sample Compartment Accommodate 5-100mm Pathlength Cuvette
Detector Silicon Photodiode
Lamps Tungsten Lamp & Deuterium Lamp (Pre-aligned)
Display Graphic LCD (128x64 Dots)
Keypad 11-key Membrance Keypad
Output Port USB Port & RS232 Port
Printer Mini Serial Printer; PC Printer
PC Software Optional PC Scanning Software
Power Requirements AC 90-250V,50/60Hz
Dimension 431x318x195mm
Net Weight / Gross Weight 8.2kgs / 12kgs 9kgs / 13kgs

DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
   

 
DV-8200 / DU-8200
UV/VIS Spectrophotometer

8200 series spectrophotometer is the ideal instrument for education and QC laboratories. They are simple to fit a curve by using your standard. They are widely used in colleges and quantitative analysis lab.

Features
Small fine design, space saving
The excellent optical and electric system
Low noise and Low stray light
Large LCD display (128*64 Dots), can display curve
High quality grating, detector and lamps
Data and Curve can be stored in real-time
Auto setting WL, auto Blank
Easy to change Pri-aligned lamps
Reinforced baseboard and bracket assures durability
Function:
Photometric: T%, Abs
Quantitative: Standard Curve
System Utility
* WL Scan (Spectrum Scan) (PC)
* Time Scan (Kinetics) (PC)
* DNA/Protein Test (PC)
* Multi-WL Test (PC)
 
 Specifications:
Model DV-8200 DU-8200
Wavelength Range 320-1100nm 190-1100nm
Spectral Bandwidth 2.0nm or 4.0nm optional
Optical System Single Beam, Blazed Holographic Grating (1200 lines/mm)
Wavelength Accuracy ±0.8nm
Wavelength Repeatability ≤0.2nm
Wavelength Setting Auto, Resolution 0.1nm
Photometric Range 0~200%T, -0.3­~3A, 0~9999C
Photometric Accuracy ±0.002A (0~0.5A), ±0.004A (0.5~1A), ±0.3%T (0~100%T)
Photometric Repeatability ≤0.001A (0~0.5A), ≤0.002A (0.5~1A), ≤0.2%T (0~100%T)
Stray Light ≤0.1%T(220/360nm)
Scan Speed High, Medium, Low.  Max.1000nm/minute
Baseline Flatness ±0.003A
Stability ±0.002A/h (500nm,0A)
Noise ≤0.2%T/3min (250/500nm,0%T); ≤0.5%T/3min (250/500nm,100%T)
Sample Compartment Accommodate 5-100mm Pathlength Cuvette
Detector Silicon Photodiode
Lamps Tungsten Lamp & Deuterium Lamp (Pre-aligned)
Display Graphic LCD (128x64 Dots)
Keypad 11-key Membrance Keypad
Output Port USB Port & RS232 Port
Printer Mini Serial Printer; PC Printer
PC Software Optional PC Scanning Software
Power Requirements AC 90-250V,50/60Hz
Dimension 431x318x195mm
Net Weight / Gross Weight 8.2kgs / 12kgs 9kgs / 13kgs

DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
DV-8200 / Du-8200 UV/Vis Spectrophotometer
 

Plumbing Parts

Rubber Expansion Joints,Cleaning Vessal,Carbon Steel Tundish

Ball Valves,Butterfly Valves,Check Valves Co., Ltd. , http://www.nspressfittings.com