Table of Contents Chapter 1 General Provisions Chapter II Basic Situation of Key Parts of Fire Safety in Factory Chapter 3 Factory Fire Accident Emergency Relief Organization and Responsibilities Chapter 4 Fire Accident Prevention and Emergency Preparedness Chapter V Classification and Classification of Fire Accidents Chapter VI Fire Report of the accident and the fire of the initial fire Chapter VII End of Emergency and Site Restoration Chapter VIII Propaganda, Training and Exercises of the Fire Emergency Rescue Plan Chapter 9 Supplementary Annex 1 Startup Procedure for Fire Accident Fire Fighting and Rescue Plan Attachment 2 Fire Accident Fire Fighting Rescue The first chapter of the first chapter of the procedure is to strengthen the fire safety management of our factory, comprehensively implement the fire prevention work policy of “prevention first, anti-disintegrationâ€, timely and effectively save all kinds of initial fires, minimize the fire hazard, and combine factory fire prevention and fighting of the actual situation, according to "Jinchuan Group Ltd. beneficiation plant disaster emergency rescue sub-plan" requirements, according to "Jinchuan Group Ltd. fire fighting and rescue plan" to develop the plan. Article 2 This plan is applicable to sudden fire accidents occurred in all units of the factory. Article 3 The emergency handling of sudden fire accidents shall be led by the factory and shall be responsible for the grading. We will achieve rapid response, unified command, effective disposal, and orderly response to ensure the smooth completion of fire emergency rescue missions. Article 4 When disposing the fire safety of the plant protection area, it is necessary to adhere to the principle of people-oriented and put the safety of the workers and workers in the first place. Article 5 Establish and improve the fire emergency emergency rescue system, improve various working mechanisms, and use information technology to make the six links of “measurement, reporting, prevention, resistance, rescue and aid†closely link to form an overall synergy and improve Comprehensive forecast analysis and emergency rescue and disposal capabilities for the occurrence and development of sudden fire accidents. Article 6 In accordance with the requirements of regular combat readiness and key construction, the emergency fire rescue accident emergency rescue disposal and the volunteer firefighter training drill work shall be combined to realize fire emergency rescue in the form of emergency preparation, command procedures and rescue methods. Organic unity with the usual training drills. Article 7 The relevant departments of the factory involved in this plan shall, in accordance with the duties performed by the department in the fire prevention work, implement various support measures, perform due diligence, cooperate closely, and form a joint force to ensure a rapid emergency response when dealing with fires in the plant area. . Chapter II Basic Situation of Key Parts of Fire Safety in Factory Article 8 The whole factory covers an area of ​​about 3.25 million square meters and a building area of ​​76,000 square meters. The number of employees in the whole factory is more than 1,500, and there are 6 workshops and 8 functional departments. In the production process, all kinds of rubber belts, V-belts, heavy oil, used detonators and other flammable materials are used; in the case of chemical dangerous goods, pressure vessels, various types of equipment and electrical circuits in the field industrial test, if an accident occurs, it is easy to cause fire; All kinds of flammable materials, acetylene, oxygen turnover library, large car warehouse, all kinds of archives, all kinds of hot fires in the field of equipment maintenance, fire in winter is also easy to cause fire. The factory area is adjacent to the refinery, smelter and chemical plant of the group company. In case of fire, it may also involve our factory. Article 9 The power load of the whole plant is Grade II, the fire water source is municipal water inlet, and the branch water supply network. There are 160 fire prevention points in the whole plant, 100 bottles of 1211 fire extinguisher, 563 bottles of dry powder fire extinguisher, and aerosol type for automobile. There are 22 fire extinguishers, 10 indoor fire hydrants, and 8 outdoor underground fire hydrants. The whole factory has 188 firefighters, 20 emergency responders, and 105 key fire-resistant workers. The monthly storage capacity of flammable and combustible materials is 80 bottles of oxygen and 70 bottles of acetylene. Chapter III Plant Fire Accident Emergency Rescue Organization and Responsibilities Article 10 The concentrator shall set up a fire accident emergency rescue fire command headquarters (located in the fire accident unit), and be responsible for the fire accident emergency rescue under the leadership of the plant disaster accident emergency rescue command. jobs. The chief commander of the fire station: the deputy director in charge of the fire safety work, the deputy commander of the fire field: the person in charge of the accident department of the party committee work department: the person in charge of the production planning department, the person in charge of the safety and environmental protection department, the person in charge of the mobile energy department, and the scientific research and technical department. The main duties of the person in charge of the person in charge of the factory, the person in charge of the factory, and the person in charge of the labor union: (1) to convey and implement the decision of the emergency rescue and rescue headquarters of the factory, responsible for the comprehensive coordination of sudden fire accidents and the information communication of relevant departments. (2) Establish and improve the information linkage system for all workshops and sudden fire accidents in neighboring factories. Integrate information, timely grasp and analyze important information and propose to report to the factory for disaster emergency rescue headquarters; (3) Fully responsible for emergency rescue and disposal of fires inside the factory. Article 12 There are 7 action teams under the Fire Command: (1) Fire Fighting Action Group (approximately 50-100 people): Responsible for the head of the Party Committee Work Department, the fire unit leader and the Safety and Environmental Protection Division, and the fire unit is responsible for fire protection. The team members and other workshops are composed of volunteer firefighters. Mainly responsible for the rescue, fire fighting and other work of the fire scene. (2) Evacuation and guidance group (about 20 members): It is responsible for the fire unit leader, fire unit security officer and some employees. It is mainly responsible for evacuating the personnel and materials at the scene of the fire and ambulance the casualties on the scene. (3) Communications Group (composed of approximately 5 members); responsible for the production planning department and personnel of the Production Planning Section. Mainly responsible for the fire alarm, report, communication, uploading and other work. (4) Security and security team (about 20 members): Responsible by the head of the party committee's work department, and the factory militia emergency detachment. It is mainly responsible for traffic control during emergency rescue and warning of major targets to ensure smooth roads during rescue. (5) Logistics Support Group (approximately 20 members). Responsible for the person in charge of the Mobile Energy Division and the head of the factory office, the factory office, the mobile energy department, the safety and environmental protection department, the trade union and other factory personnel. Mainly responsible for vehicle deployment, relief supplies, recycling, treatment, fire site circuit control, water source protection and medical rescue. (6) Accident investigation team (about 10 members): Responsible for the person in charge of the work department of the party committee and the person in charge of the safety and environmental protection department. It is composed of personnel from the Department of Mobile Energy, Production Planning, Safety and Environmental Protection, Scientific Research and Technology, and Trade Union. Mainly responsible for fire site investigation, forensics and accident analysis, investigation and handling, and cooperate with the superior fire department to carry out investigation and handling of fire accidents. (7) After-treatment group (about 5 members): Responsible by the person in charge of the trade union, composed of personnel from the Safety and Environmental Protection Department, the Finance Department, and the Human Resources Department. Mainly responsible for the appeasement of the casualties and after-treatment. Chapter IV Fire Accident Prevention and Emergency Preparedness Article 13 All workshops and relevant departments must actively do in accordance with the provisions of the relevant laws and regulations, such as the Fire Protection Law of the People's Republic of China, the Fire Safety Management Regulations of Organs, Organizations, Enterprises and Institutions. All kinds of fire disaster accident prevention work in the good factory area, resolutely prevent all kinds of heavy and extraordinarily large fire disasters. Article 14 All units shall take the volunteer firefighters as the main body, set up corresponding emergency rescue teams for sudden fire accidents, and combine various workshops to carry out various forms of fire prevention professional skills training and training to improve emergency rescue of sudden fire accidents. The team's rapid response capability and staff on-site disposal capabilities. Article 15 All units shall, according to the degree of hazard and the scope of impact of fire accidents, plan emergency shelters in emergency situations, such as fire rescue team assembly sites, wounded rescue sites, and rushed materials storage places, etc. brand. Article 16 Organizers or departments that hold major exhibitions, cultural and sports events, etc. must formulate emergency plans for temporary fire prevention. Chapter V Division and Level of Fire Accidents Article 17 A fire accident refers to a disaster caused by loss of control in time or space and caused to personnel and property. According to the State Council's "Special Major Public Event Classification Standards (Trial)", the fire accident grading standards are: (1) Extraordinary (Class I): more than 30 deaths at a time; (2) Major (Level II): More than 10 deaths; Seriously injured more than 20 people; more than 20 people were killed or seriously injured; more than 50 people were affected; direct economic losses are expected to be more than 1 million yuan; (3) Larger (level III): 3 or more deaths and 10 or less; serious injuries of 10 or more and 20 people The following; death, serious injury 10 or more and 20 or less; affected by 30 households with more than 50 households; direct economic loss is expected to be less than 300,000 yuan and less than 1 million yuan; (4) general (level IV): fail to meet the standard III fire ACCIDENT. Article 18 The emergency rescue plan for fire accidents in our factory is mainly responsible for the following emergency rescues for general fire accidents (response level; level IV). If the standard above IV is reached, the factory emergency rescue headquarters immediately requests to start the emergency rescue plan for the heavy and extraordinarily large fire accidents of the group company. The factory accident emergency rescue headquarters was transferred to cooperate with the implementation of the group company plan. Chapter VI Report of Fire Accidents and Fighting of Initial Fires Article 19 Fire Accident Reporting Procedures (1) When a fire accident occurs, the on-site personnel immediately report the dispatching of the plant and the person in charge of the workshop or the staff on duty in the workshop, the person in charge of the workshop or the workshop on duty. According to the report, the personnel should promptly go to the scene of the fire to quickly find out the following situations: 1. The location of the fire, the nature of the burning materials, the fire range, the fire spread route and the development direction; 2. Whether anyone is trapped and found trapped Number of personnel and location and best evacuation route; 3. Whether there are explosive or toxic substances, check the quantity, storage location, storage form and degree of danger; 4. Identify the quantity and storage point, storage form and storage of valuable property The extent of the threat of fire determines whether evacuation and protection are required; 5. The structure of the fire building, the fire resistance rating, the distance from the adjacent building, the risk of collapse of the fire building, and the need for the site to be demolished. And report the above situation together with the reporting unit and the name of the reporter to the dispatching room immediately and accurately. At the same time, the company fire alarm directly to the group company fire brigade (88 telephone dialing 119, other telephone dialing 8811119, 8812119, 8825119, 8827119). (2) The workshop shall immediately organize the unit's rescue equipment and strength, and fully carry out self-rescue to prevent the spread of fire accidents. (3) After receiving the alarm call from the workshop, the dispatching office of the factory immediately reports the emergency rescue headquarters of the fire accident. According to the command of the command, it promptly issues the power-off instruction of the fire unit and makes detailed records. Article 20 After receiving the alarm, the disaster emergency command headquarters of the factory may confirm the emergency response level according to the fire situation, decide to start the emergency rescue plan of the factory or request the group company to start the emergency rescue plan for the heavy and extraordinarily large fire accidents of the group company. And immediately notify the fire accident emergency rescue fire brigade command members quickly arrived. After receiving the order, the fire emergency command team members will promptly organize relevant departments according to the requirements and responsibilities of the plan, and mobilize the relevant responsible departments to rush to the scene according to the type and nature of the fire accident, and organize the implementation of the rescue according to the procedures of the fire accident emergency rescue plan. Rescue and emergency disposal operations, timely control the development and spread of the situation, and timely report the situation to the factory disaster emergency rescue headquarters. Article 21 The professional teams of fire accident emergency rescue shall be responsible for the unified deployment of the emergency fire station command department of the factory fire accident, and shall be responsible for the work in charge. (1) Fire-fighting Action Group: After receiving the alarm, all members immediately rushed to the scene of the fire. After accepting the task, according to the fire situation at the scene of the fire, quickly formulate a fire-fighting action plan, rationally deploy the fire-fighting force, and use the nearest fire-fighting facilities (fire extinguishers, Fire hydrant), timely organize the implementation of rescue personnel and fire fighting. In the firefighting, we must follow the command, cooperate with each other, cooperate with each other, pay attention to safety, and strive to save. In response to changes in the current situation of the fire, timely and decisive adjustment of the corresponding fire-fighting measures, to extinguish the initial fire as soon as possible. After the arrival of the fire brigade of the group company, the firefighting team leader shall truthfully and accurately reflect the situation of the scene to the fire brigade personnel. After the fire brigade takes over the command, the fire fighting operation team will be transferred to cooperate with the fire fighting work. (2) Evacuation guiding group: by fire unit The leader or security officer unified command and quickly evacuate the personnel and property at the scene of the fire, with the focus on the old workers and female employees who need help. Under the possible conditions, evacuate important information documents and valuable property, and strive to reduce fire damage. During the evacuation process, a hand-held loudspeaker is used to call or make gestures to guide the field personnel, evacuate through the nearest evacuation channel, and ensure that there is personnel at each evacuation channel to guide evacuation. In the case of a long ambulance distance, relay rescue is used, and rescuers must be placed at different locations. For more complex fire scenes and rescue routes, ambulance personnel should mark them when entering. (3) Communication contact group: After receiving the alarm, it promptly reports the emergency fire rescue headquarters of the factory fire accident, and immediately starts the emergency rescue plan for the sudden fire accident according to the command of the headquarters and promptly reports to the fire brigade of the group company. (88 telephones dial 119, other telephones dial 8811119, 8812119, 8825119, 8827119), when the alarm, accurately reflect the situation, and send people to the fire truck. According to the order of the on-site command, the power-off command will be issued to the fire unit in time. Ensure that the fire scene communication is uploaded and delivered in a smooth and orderly manner. In case of encounters involving adjacent units, it is responsible for timely notification. (4) Security and security team: After receiving the alarm, all members immediately rushed to the scene of the fire to meet with the members of the on-site command. Immediately after receiving the task, they immediately set up a warning line according to the scene of the fire to maintain order on the scene and ensure traffic during emergency rescue. Smooth and primary target alert and necessary traffic control to assist in evacuating the workforce. (V) Logistics Support Group: After receiving the alarm, all members immediately rushed to the scene of the fire to meet with the members of the on-site command. After accepting the task, they should urgently call the rescue materials and equipment needed for the fire scene according to the specific conditions of the rescue mission and personnel composition. To ensure the supply of consumables such as combat suits, air respirator bottles, fire extinguishing agents, decontaminants, oil materials and special rescue equipment (accessories) required for rescue operations (the standing fire-fighting equipment is under the responsibility of the fire department responsible department, and the sudden fire accident Rescue materials and equipment need to be allocated by the factory); organize technical personnel to inspect the equipment and appliances affected by the fire in time, determine the scope of power outage, and notify the headquarters in time. Guarantee the rescue, food, medical and vehicle transportation and other security work. (VI) Accident investigation team: After the fire is extinguished, the accident investigation team quickly enters the fire unit, and conducts on-site investigation, evidence collection, investigation and analysis with the relevant departments, and submits a fire accident investigation report to the factory emergency fire emergency headquarters within one week. Fire accident investigation work with excessive factory authority shall be coordinated in accordance with relevant regulations. (7) After-treatment group: It is composed of the staff of the trade union and is responsible for security, finance, human resources and other departments. Mainly responsible for the appeasement of the casualties and after-treatment. Article 22 Requirements for Emergency Rescue Sites (1) After a fire accident occurs, the accident unit must strictly protect the site. Any objects, traces and conditions related to the accident shall not be moved or destroyed at will. If the rescue work needs to be moved, it should be marked and detailed by means of photographing and drawing a map. (2) Maintain good communication links between the fire scene command and the professional rescue teams. (3) Rescue vehicles must obey the dispatch of the command and drive and park as required by the on-site traffic management personnel. (4) Explosion-proof equipment and tools shall be used for the rescue of large quantities of flammable and explosive hazardous materials. Emergency rescue personnel must strictly dress regulations and must not wear clothing such as nailed shoes or chemical fiber clothing that may cause Mars. Turn off communication tools such as mobile phones in time. Chapter VII Emergency End and Site Restoration Article 23 The direct emergency rescue mission of the fire accident and the end of the rescue activities of the on-site casualties, and the impact of the fire accident are initially controlled, and after the on-site inspection and evaluation, there is no harm and risk. The on-site emergency rescue command will be cancelled, and the on-site emergency response work will be completed. The emergency response headquarters of the factory will announce the emergency end. Article 24 Fire units shall continue to maintain or take necessary measures to consolidate the results of fire emergency response work according to actual conditions and needs, and prevent fire secondary and derivative accidents. Article 25 After the emergency operation is completed, the accident investigation team of the disaster emergency headquarters of the factory shall immediately conduct or assist the office of the emergency headquarters of the group company to investigate the impact of the fire accident, verify the loss, and respond to the fire emergency. The comprehensive situation of the disposal work is summarized, and the material reporting factory and the relevant departments at the higher level are formed. Article 26 After the emergency operation is over, the factory shall uniformly lead and coordinate the recovery and reconstruction work after the fire accident, organize the fire accident units and the competent departments to report the number of casualties and damages, organize the forces to rescue themselves, collect and clean up in time. And to deal with pollutants, restore communication, water supply, drainage, power supply, gas supply and other infrastructure as soon as possible, restore normal production order, and maintain stable and stable factory. Chapter VIII Propaganda, Training and Exercises of Fire Emergency Rescue Plan Article 27 The emergency fire rescue headquarters of the factory and the relevant functional departments shall actively organize publicity activities to publicize the emergency response to the fire disaster. Countermeasures, disposal knowledge and self-help common sense. Provide relevant knowledge and skills training to employees in an organized and planned manner. Article 28 The factory will regularly organize training courses for the emergency fire rescue headquarters staff and the workshop volunteer firefighters. Training on fire professional knowledge, laws and regulations and emergency handling procedures to ensure efficient and orderly implementation of emergency response work. All workshops should also increase investment, strengthen business training on professional skills and self-protection of fire fighting and rescue teams in this department, and improve the actual combat capability of professional emergency rescue teams. Article 29 The factory shall organize emergency rescue drills for sudden fire accidents at least once a year, and shall be organized and implemented by the emergency fire rescue headquarters of the factory. From the perspective of actual combat, the drill should mobilize and rely on the staff and the masses to popularize the knowledge and skills of emergency rescue and effectively improve the emergency rescue capability of sudden fire accidents. Chapter IX Supplementary Provisions Article 30 The implementation of reward and punishment systems for emergency rescue and disposal of sudden fire accidents. In accordance with the relevant provisions of the "Conservation Plant Disaster Accident Emergency Relief Division". Article 31 This plan is a special plan for the “Emergency Rescue Sub-plan for Disaster Accidents of Jinchuan Group Co., Ltd. Concentratorsâ€, which is explained by the Party Committee Work Department. Article 32 This plan shall be formulated, revised and improved in accordance with relevant laws and regulations as well as the problems found in the emergency handling process and various types of emergency drills, as well as new situations arising from the revision and improvement of the time and the major disasters of the concentrator of Jinchuan Group Co., Ltd. The accident emergency rescue sub-plan is synchronized. Article 33 This plan shall be implemented as of the date of promulgation. Annex 1 The starting procedure for the fire accident rescue plan for fire accidents is the level standard for the start-up plan: (1) Starting below level IV: initial fires occur in key parts of non-fire prevention, using on-site fire-fighting facilities, and confidently based on fire-fighting; (2) Level IV start-up : Local fire occurred, 2 people were trapped below, the fire was detected and alarmed within 5 minutes. When the fire brigade arrived, the spread range was not significantly increased, and it was safe to extinguish the fire in one fell swoop; (3) Level III start-up: local fire There are more than 2 people, people under 10 are trapped, the fire begins to spread, and the danger is big, but the fire brigade can control the fire and have a sure fire; (4) Level II start-up: fire in a large area, with more than 10 people Under 30 people are trapped, the whole building has the danger of complete burning, and can cause casualties. The existing strength of the fire brigade can control the fire, and the auxiliary fire extinguishing force must be increased. (5) Level I start: comprehensive Burning, more than 30 people are trapped, the fire is spreading to the surrounding danger, it may cause serious personal injury and death, and has a major political impact and heavy economic losses, need Automatic Sliding Door Operators High quality door residential automatic door opener
Carton+Foam+Bubble Bag and Pallet
Safety & Operation Devices of High Speed PVC Roll up Door:
In consideration of operation safety for high speed PVC roll up door, we provide the photo cell, and wireless safety airbag device as the standard safety device; And to enrich the operation methods of the high speed door, various options are provided such as manual button, transmitter, control box, radar sensor and inductive loop device. Different styles of transparent window are also available for better vision view.
Varied Running Speed of High Speed PVC Roll up Door:
Running speed of High Speed PVC Roll up Door is adjustable: Opening speed from 0.80m/s to 2.0m/s, and closing speed from 0.6m/s to 1.0m/s. Running speed adjustment can be achieved through inverter inside the control box, t to meet the actual needs.
Driving System of High Speed PVC Roll up Door:
Driving system is the core part for the high speed roll up doors. For the motors, we can provide multiple options for different demands, brands including SEW, SIEMENS, SNMA, SEJ and Servo Motor; All the motors are provided with manual brake, that offers emergency operation under power failure. Furthermore, motor power can be applied based on the real door size, in supply voltage 220V single phase and 380V three phase.
sliding door operators, automatic door motor opener, door accessory ,automatic door operators,fast door accessory SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfafrud.com