Ground And Water Source Heat Pump Ground Source Heat Pump,Water Source Heat Pump,Water To Water Heat Pump,Water & Ground Source Heat Pump,Geothermal heat pump water heater and cooler,Intelligent Control Heat Pump Guangdong Shunde O.S.B. Environmental Technology CO.,LTD. , https://www.heatpump-osb.com
RVVP2*32/0.2 R: Cord VV: Double sheathed wire P shield 2: 2 core multi-strand wire 32: 32 copper wires per core 0.2: Each copper wire has a diameter of 0.2 mm
What kind of wire and cable knowledge do you need to master in weak electrical security?
There are many types of weak electric cables. The cable types used in each system are different and their functions are different. It is necessary for friends who are weak in electricity to understand the commonly used weak electric cables.
First, the definition of wire and cable
Wire and cable refers to materials used in power, communications, and related transmission applications. There are no strict boundaries between "wires" and "cables." A product having a small number of cores, a small product diameter, and a simple structure is generally referred to as a wire, and a non-insulated product is called a bare wire, and the other is called a cable.
Second, weak electric cable naming principle
1. Content included in the product name:
(1) Product application or size class name
(2) product structure materials or types;
(3) Important or additional features of the product
Basically named in the above order, sometimes in order to emphasize important or additional features, the features are written before or before the corresponding structure description.
2, the order of structure description
The product structure is described from the inside to the outside: conductor -> insulation -> inner sheath -> outer sheath.
3, simplified
Some structural descriptions are either written or abbreviated without causing confusion. E.g:
SYV 75-5-1 (A, B, C) S: RF Y: Polyethylene insulation V: PVC sheath A: 64 series B: 96 series C: 128 series 75: 75 ohms 5: wire diameter 5MM 1: represents a single core
SYWV 75-5-1 S: ​​RF Y: Polyethylene insulation W: Physical foaming V: PVC sheath 75:75 ohms 5: Cable outer diameter is 5mm 1: Represents single core
ZR-RVS2*24/0.12 ZR: Flame Retardant R: Cord S: Twisted Pair 2: 2 core multi-strand wire 24: 24 copper wires per core 0.12: Each copper wire has a diameter of 0.12mm
Third, the composition of weak electric cable
It consists of an inner conductor, an insulation, an outer conductor and a sheath from the inside out;
Inner conductor: Since the attenuation is mainly caused by the resistance of the inner conductor, the inner conductor has a great influence on the signal transmission.
Insulation: affects attenuation, resistance, return loss and other properties
Outer conductor: return conductor, shielding
Fourth, the common cable code meaning
RVVP : copper core PVC insulated and sheathed PVC sheathed flexible cable voltage 300V/300V 2-24 core use: instrument, instrument, intercom, monitoring, control installation
KVVP: PVC sheathed braided shielded cable Uses: Signal transmission, control, measurement of electrical, instrumentation, and distribution equipment
SYWV ( Y ), SYKV cable TV, broadband network dedicated cable structure: (coaxial cable) single oxygen-free round copper wire + physical foamed polyethylene (insulation) + (tin wire + aluminum) + polyvinyl chloride (polyethylene) )
RVV PVC insulated flexible cable Uses: household appliances, small power tools, instruments and power lighting
AVVR PVC sheathed flexible cable
RV, RVP PVC insulated cable
RVS and RVB are suitable for household appliances, small power tools, instruments, meters and power lighting connection cables.
BV, BVR PVC insulated cable Uses: Suitable for electrical instrumentation equipment and power lighting fixed wiring
V. Examples of selection of common weak current cables
The distance between the video line camera and the monitoring host is ≤200 meters, and the SYV75-3 video cable is used. The distance from the camera to the monitoring host is >200 meters, using the SYV75-5 video cable. Network digital video surveillance, camera transmission using twisted pair transmission, such as cat5e, cat6 and so on.
The distance between the pan/tilt control line and the controller is ≤ 100 m, and the RVV 6×0.5 sheathed wire is used. The distance between the pan/tilt and the controller is > 100 m, and the RVV6×0.75 sheathed wire is used. In practice, RVVP2*075 is generally used.
Cables used in building intercom systems are mostly RVV, RVVP, SYV and other cables.
Six, the difference between common weak electric cables
The difference between SYV and SYWV: SYV is a video transmission line, insulated with polyethylene. SYWV is an RF transmission line with physical foam insulation. For cable TV.
RVS differs from RVV 2 core: RVS is a twisted pair of two-core RV wires with no outer jacket for broadcast connections. The RVV 2-core cable is directly cabled and has an outer jacket for power supply and control signals.
RVV and KVV RVVP and KVVP difference: The line used in RVV and RVVP is composed of a flexible wire composed of multiple thin copper wires, that is, RV lines. The wire used in KVV and KVVP is a hard wire consisting of a single thick copper wire, that is, a BV wire.
The difference between AVVR and RVVP: AVVR refers to unshielded cable with wire diameter less than 0.5MM, and RVVP refers to shielded cable with wire diameter greater than or equal to 0.5MM.
RVS differs from RVV 2 core: RVS is a twisted pair of two-core RV wires with no outer jacket for broadcast connections. The RVV 2-core cable is directly cabled and has an outer jacket for power supply and control signals.